EMP006 72V 5500W 3680RPM 89.87Amp 14.27Nm B3/B14/B34/B5 Controller brushless BLDC for electromobile

  • USD $350 - $400 / Piece Get Latest Price
  • HF Motion
  • EMP006
  • Zhejiang, China
  • 100 Piece / Pieces
  • T/T Credit Card
  • 500 Piece / Pieces per Month
  • Ningbo or Shanghai
Product Details
Torque:14.27Nm, 14.27Nm Construction:Permanent Magnet Efficiency:IE 4
Continuous Current(A):89.87Amp Speed(RPM):3680rpm Commutation:Brushless
Product Description

Product Display

VIEW MORE PLS CONTACT US >>>

Other Products

Process Flow

About Us

Packing&Transport

Q:Motor has been running then fails to start,what to do?A:Likely cause: Fuse or circuit breaker is tripped. 

      What to do: Replace the fuse or reset the breaker.

     Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.      What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.

     Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.      What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.

      Likely cause: Controller may be defective.       What to do: Verify voltage is coming out of the controller.

Q: On initial installation, motor fails to start up,what to do?A: Likely cause: Motor is incorrectly wired      What to do: Verify that the motor is wired correctly.

     Likely cause: No output power from controller.      What to do: Measure voltage coming from the controller.

     Likely cause: Motor is damaged and the armature is rubbing against the magnets.      What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.

Q:  Motor takes too long to accelerate,what to do?A:  Likely cause: Motor controller not properly set.      What to do: Adjust the acceleration trim pot of the controller.

     Likely cause: Brushes are worn.      What to do: Verify brush length.

     Likely cause: Bearings may be defective.      What to do: Inspect bearings. Noisy or rough bearings should be replaced.

Q:  Motor runs in the wrong direction,what to do?A:  Likely cause: Incorrect wiring      What to do: Interchange the two motor leads.

Q:  Motor runs OK but has a clicking noise,what to do?A:  Likely cause: Suspect a burr on the commutator.      What to do: Remove burr from commutator using a commutator stone.